If your LG refrigerator is showing Er DS, you’re seeing a defrost sensor fault. That sensor plays a small but critical role: it tells the fridge when the evaporator needs defrosting. When the control board gets a signal that doesn’t make sense (an open circuit, a short, or wildly wrong resistance), it flags Er DS to protect the system from improper defrost cycles. Below is a clear, SEO-friendly guide that explains the fault, common causes, safe DIY checks and fixes, and simple preventative steps — all in plain American English and easy to follow.

Quick symptoms (what you might notice)

What the “Er DS” error actually is

The defrost sensor (also called a defrost thermistor or temperature sensor) monitors the evaporator temperature during defrost cycles. If the sensor circuit is cut, shorted, or reading out of range, the fridge won’t correctly manage defrosting. Too little defrosting lets ice build up and reduces cooling efficiency; too much can stress components. The fridge shows Er DS to tell you the sensor reading is invalid and needs attention.

Common causes (short list)

Safety and tools before you start

Before you open anything, unplug the refrigerator or flip the breaker. Wait for the freezer to warm a bit if it was very cold. If you don’t feel comfortable with basic electrical checks, stop and call a qualified technician.

Tools you may need:

DIY diagnostic and simple fixes (step-by-step)

  1. Power down the fridge — unplug it or switch off the breaker. Safety first.
  2. Open the freezer section and remove the back panel to access the evaporator area (consult your model’s manual for panel removal).
  3. Visually inspect the defrost sensor and its wiring for cuts, crushed insulation, or corrosion where the connector plugs into the harness.
  4. Disconnect the sensor from its harness and set your multimeter to measure resistance (ohms). At room temperature, most defrost sensors show a specific resistance — check your model’s manual if you have it. If the reading shows open circuit (OL) or an obviously shorted value (near 0 Ω), the sensor is bad.
  5. If the sensor resistance looks reasonable, check continuity and condition of the wiring from the sensor to the control board. Wiggle the harness while watching the meter — intermittent faults often appear this way.
  6. If you find a damaged wire or connector, repair or replace the wiring harness and retest. If the sensor itself is bad, replace it with an OEM or exact-match part for your model.
  7. After repairs, reassemble panels, restore power, and monitor the fridge for a normal defrost cycle and that Er DS no longer appears.

When a simple reset helps

Sometimes the code is transient. Try this:

When to call a pro

Preventive measures (keep Er DS away)

Quick troubleshooting checklist (short)

Final notes

Er DS is usually fixable and often traced to wiring or the sensor itself — both of which are manageable for a confident DIYer with a multimeter. Address it promptly: unresolved defrost-sensor problems lead to ice buildup, poor cooling efficiency, higher energy bills, and risk of more costly repairs.